Peri-implantitis around ceramic vs titanium implants: what the evidence actually shows
Marketing often implies that ceramic (usually zirconia) implants are “more resistant” to peri-implantitis than titanium. The literature is less absolute.
Comparative clinical studies and recent meta-analyses have not shown a clear reduction in peri-implantitis or biological complications for zirconia versus titanium. Some laboratory work shows less early biofilm on zirconia. Mature biofilms and clinical disease rates look far more similar. Patient factors — hygiene, history of periodontitis, smoking, and recall — still outweigh material choice for most people.
This article summarises long-term studies, retrospective and prospective series, systematic reviews, and mechanistic work for implantologists, periodontists, and referring GDPs. I write as a general dental practitioner with a special interest in implant dentistry — not as someone selling one material system.
What we mean by peri-implant disease
Peri-implant mucositis is soft-tissue inflammation without progressive bone loss. Peri-implantitis adds progressive crestal bone loss beyond initial remodelling, usually with bleeding and/or suppuration. Definitions still vary across studies (bone-loss thresholds, probing criteria), which is why prevalence numbers jump between papers. That heterogeneity matters when someone quotes a single “peri-implantitis rate” for ceramic implants.
Important distinction: a zirconia implant (the fixture in bone) is not the same as a zirconia abutment on a titanium fixture. Soft-tissue colour and plaque behaviour around abutments are a related but separate evidence base. This piece focuses on ceramic/zirconia implants versus titanium implants.
Why ceramic is said to resist peri-implantitis — mechanisms
Claims usually rest on four ideas:
1. Less early biofilm adhesion
In vitro and early human disk studies sometimes show less bacterial coverage on zirconia. Scarano and colleagues reported bacterial surface coverage after 24 hours of 19.3% ± 2.9 on titanium versus 12.1% ± 1.96 on zirconia (p = 0.0001) in a human *in vivo* disk model (*J Periodontol* 2004; DOI 10.1902/jop.2004.75.2.292). Later work has found less early biofilm on zirconia at a few days, with mature biofilms often looking similar. A broader synthesis of biofilm parameters likewise found bacterial *coverage* favouring zirconia in places, while other measures were inconsistent — overall, there is no clear material preference that maps cleanly to clinical disease.
2. Surface chemistry and corrosion
Titanium can release particles or ions under wear or acidic biofilm conditions. Observational work has linked higher dissolved titanium in plaque to peri-implantitis sites. That is an association, not proof that corrosion is the primary cause of disease in routine care. A critical review by Mombelli, Hashim and Cionca concluded there is insufficient evidence for a unidirectional causal relationship between titanium biocorrosion/particles and peri-implantitis (DOI 10.1111/clr.13305). Zirconia does not corrode like a metal — a real materials difference — but clinical peri-implantitis still occurs around ceramic fixtures when plaque and host susceptibility are present.
3. Soft-tissue seal and aesthetics
Preclinical comparisons have found broadly similar hard- and soft-tissue integration capacity for zirconia and titanium. Zirconia abutments can improve soft-tissue *colour* versus titanium; health indices (probing, bleeding, recession) are generally similar. Aesthetics are a stronger ceramic argument than peri-implantitis immunity.
4. Animal ligature models
In a canine ligature model, Roehling and colleagues reported less experimental bone loss on zirconia versus titanium during *active* progression, with no significant difference after spontaneous progression alone (DOI 10.11607/jomi.7015). Experimental models are not human peri-implantitis prevalence.
Takeaway on mechanisms: early biofilm may favour zirconia modestly; mature biofilm and clinical disease do not establish ceramic as disease-proof.
What comparative reviews and meta-analyses show
ZrO Summit 2025, Group 4
This systematic review compared biological complications and peri-implant tissue response for zirconia versus titanium implants (≥12 months follow-up). Six studies (five RCTs and one cross-sectional; 354 implants) met inclusion. For biological complications (peri-implant mucositis or peri-implantitis) across three studies with 12–60 months follow-up, there was no significant difference: risk ratio 0.95 (95% CI 0.80–1.12). At 12 months, bleeding on probing was higher around zirconia (mean difference 4.72; 95% CI 0.90–8.54; p = 0.02), without matching differences in plaque index, probing depth, or pink aesthetic score. Certainty was moderate for biological complications and low for the soft-tissue indices. Authors’ conclusion: comparable biological performance; the isolated BoP finding needs longer, larger trials (DOI 10.11607/jomi.11786).
Prevalence of peri-implantitis around zirconia implants (2026)
A separate systematic review pooled 19 studies (687 patients, 995 implants; mean follow-up about 49 months). Implant-level peri-implantitis prevalence estimates rose with time: about 2% at ≤3 years and at >3–5 years (wide confidence intervals), and about 8% (95% CI 0–23%) beyond 5 years — with substantial heterogeneity. In five RCTs comparing zirconia and titanium, there was no statistically significant difference in peri-implantitis (RR 1.66; 95% CI 0.48–5.71; p = 0.42). Authors stressed limited certainty, inconsistent definitions, and scarce long-term comparative data (DOI 10.1111/cid.70176).
Marketed zirconia at five years and beyond (ITI / Roehling 2023)
Restricting to commercially available zirconia systems with ≥5 years of observation, Roehling and colleagues pooled six cohorts (277 implants / 221 patients for survival): survival 97.2% (95% CI 94.7–99.1), mean marginal bone loss 1.1 mm (0.9–1.3), probing depth 3.0 mm (2.5–3.4). In that analysed set, peri-implantitis incidence at last follow-up was 0.4% — a small absolute number in a still-modest evidence base, not a licence to claim immunity (DOI 10.1111/clr.14133).
Can material be called a peri-implantitis risk factor?
A 2025 systematic review asking whether implant material (titanium vs zirconia) is a risk factor for peri-implantitis concluded it was not possible to draft a solid conclusion linking material to disease onset. Bleeding on probing was generally similar; marginal bone loss results were mixed; plaque and microbes sometimes favoured zirconia (DOI 10.1007/s12663-024-02409-9; PMC 12316646).
Head-to-head RCT meta-analyses remain thin. Padhye and colleagues found only two RCT populations for zirconia versus titanium survival/success synthesis, with a non-significant survival difference at 12 months (DOI 10.1007/s00784-023-05242-5).
Long-term ceramic evidence (often without a titanium control arm)
Long zirconia follow-ups are useful for absolute rates, weaker for “resistant versus titanium” claims.
First-generation systems paid a mechanical price. Roehling and colleagues’ retrospective of early sandblasted zirconia (71 patients, 161 implants, up to and after 7 years of loading) reported overall survival about 77%, driven by early failures and fractures — not by infection. Surviving implants showed healthy soft-tissue indices; none of the evaluated implants had a history of peri-implant infections (DOI 10.1111/cid.12323). Biology in survivors looked calm; that does not make early zirconia a modern clinical recommendation.
Modern one-piece marketed systems look better on survival. Examples locked from primary reports:
Balmer et al.: one-piece Y-TZP, 5 years — survival 98.4% (95% CI 91.6–99.9); MBL 0.7 ± 0.6 mm (DOI 10.1111/clr.13581).
Kohal et al.: ATZ one-piece, 5 years — survival 94.3%; MBL about 0.8 mm (DOI 10.3390/jcm9082585).
Lorenz et al.: mean 7.8 years — 100% survival, MBL 1.2 mm, one therapy-resistant peri-implantitis among 83 implants (DOI 10.1111/cid.12720).
A never-marketed rough-coated Y-TZP system (ZiUnite) had about 78% five-year survival with frequent infection — do not generalise that failure mode to current commercial ceramic implants (DOI 10.3390/jfb14020116).
Small RCT noise (do not rank materials from this alone)
A five-year monotype RCT in the anterior maxilla (n = 30) found no significant differences between zirconia and titanium for clinical, radiographic, and aesthetic outcomes. Full-text disease counts were tiny: peri-implantitis roughly 3/16 zirconia vs 2/14 titanium at 60 months — useful only to illustrate that disease occurs in both arms and that small denominators create noisy percentages (DOI 10.1111/clr.14319).
Titanium context (so ceramic numbers are not misread)
Most epidemiology of peri-implantitis comes from titanium populations. Definitions, era, surfaces, and patient pools differ from zirconia case series. Do not subtract a zirconia 2–8% implant-level figure from a titanium patient-level review and call it a material win. Matched comparative trials and meta-analyses remain the fair test — and those have not shown a significant peri-implantitis advantage for zirconia.
Practical takeaways
Do not consent patients with “ceramic won’t get peri-implantitis.” Comparative reviews show similar biological complication rates; zirconia can and does develop mucositis and peri-implantitis.
Early lab biofilm ≠ long-term clinical immunity. Less plaque at 24 hours does not cancel a 5–10-year disease process driven by hygiene and host risk.
Separate biology from mechanics. Older zirconia failures were often fractures and early loss. Newer generations improve survival; that is not the same as proving lower peri-implantitis than titanium.
Case selection still rules. History of periodontitis, poor plaque control, smoking, uncontrolled diabetes, and irregular maintenance dominate risk for both materials.
Choose ceramic for the right reasons. Thin biotype aesthetics, metal-free preference, and patient values are legitimate. “Immune to peri-implantitis” is not.
Maintenance is non-negotiable for both systems — supportive peri-implant care, early mucositis treatment, and honest radiographic baselines.
As a GDP with a special interest in implant care, the useful referral conversation names material options, aesthetic trade-offs, and the shared need for lifelong plaque control — not a miracle surface.
Short FAQ
Are ceramic implants resistant to peri-implantitis? Not in the sense comparative trials prove. Meta-analyses find no significant difference in biological complications versus titanium; disease still occurs around zirconia.
What do long-term zirconia studies show? Modern marketed one-piece systems can show high five-year survival (pooled about 97% in one ITI synthesis) with low-to-moderate biological complication rates in selected cohorts. First-generation series had more mechanical failures; survivors often lacked infection history.
Is biofilm lower on zirconia? Sometimes early (for example Scarano 2004 disk coverage). Mature biofilms are often comparable. Clinical BoP was even slightly higher for zirconia at 12 months in one pooled analysis, without more disease in that window.
Should I recommend ceramic to prevent peri-implantitis? Recommend ceramic when aesthetics or metal-free preference matter. Prevent disease with risk assessment, surgery quality, prosthesis design, and maintenance — for either material.
Key papers
ZrO Summit 2025 Group 4 SR/MA — DOI 10.11607/jomi.11786
Peri-implantitis prevalence around zirconia implants SR — DOI 10.1111/cid.70176
Marketed zirconia ≥5 years (Roehling / ITI) — DOI 10.1111/clr.14133
First-generation zirconia retrospective (Roehling 2016) — DOI 10.1111/cid.12323
Material vs peri-implantitis SR — PMC 12316646
Scarano early adhesion — DOI 10.1902/jop.2004.75.2.292
Titanium particles critical review — DOI 10.1111/clr.13305